The Elster Falcon PR6 pulse generator is a leading inductive pulser specially designed for Elster water meters. It provides accurate and reliable water consumption measurements, ideal for agricultural and industrial applications.

Article number: 27-0000025678
Type Pulse Generator:
Amount:



Description

Stable Brothers is proud to include the Elster / Honeywell Falcon Pulse Encoder PR6 in our range, a leading inductive pulser for Elster water meters. This technology allows you to obtain accurate and reliable measurements of your water consumption.

Applications of PR6:

The Elster Honeywell Falcon PR6 pulse generator is specially designed for use with Elster water meters. It is commonly used in situations where accurate measurement of water consumption is essential, such as in agricultural applications, industrial settings and municipal water supply systems.

Most important features:

  • Inductive pulser specifically designed for Elster water meters, guaranteeing that the pulser works seamlessly with your existing water meter.
  • Delivers an accurate output of 1 litre/pulse, 10 litres/pulse, 100 litres/pulse and 1000 litres/pulse, meaning you can monitor your water consumption to the nearest litre.
  • Provides consistent and reliable results, giving you a clear and accurate insight into your water consumption.

Specifications

Type K Factor Primary Pulse Value Secondary Pulse Value
PR6 1:1 PR6P:1 1 litre/pulse 1 litre/pulse
PR6 1:10 PR6P:1 1 litre/pulse 10 liters/pulse
PR6 1:100 PR6P:1 1 litre/pulse 100 liters/pulse
PR6 1:1000 PR6P:1 1 litre/pulse 1000 liters/pulse

Wiring and Functions:

  • Red Wire (CH2P) : This is the secondary pulse output. This output is compensated and recommended for general data logging, external displays or AMR equipment.
  • Yellow Wire (CH1P) : This is the primary pulse output. This output is especially useful when reverse flow monitoring is required.
  • Green Wire : Indicates when compensation is taking place by going to the low state during backflow compensation.
  • Brown Wire : Is the alarm output. It activates to the high state when the PR6/7 is removed from the meter and also when the PR6/7 battery is low.
  • Black Wire (GND) : Serves as common or 0v wire.

Quality and Reliability:

At Stable Brothers we strive for quality and reliability in everything we do. By purchasing the Elster / Honeywell Pulse Encoder PR6, you can rely on the excellent quality and reliable performance of our product range. Our commitment to quality means you can count on accurate and reliable results, every time.